CAREvent® MRI Transport Ventilator is a pneumatically powered, time/volume cycled, intermittent, positive pressure patient Ventilator for use within the MRI environment. Provides a comprehensive range of 12 ventilation frequencies and 12 minute volume setings, providing 144 possible combinations of delivered tidal volume and respiratory rate. Micro-pneumatic circuitry maintains a consistent inhalation-to-expiration ratio (set at 1:2) and uses virtually no drive gas.
The various modes of operation support the resuscitation and transportation of a wide range of patients (from infants to adults) who require ventilatory support. Includes durable, portable control module with integrated carry handle, 6' input hose, and deluxe single-use transport ventilation circuit, calibrated test lung, universal facemask, and operating instructions. Two-year warranty against manufacturer defects. 9-1/4,"W x 6-1/2"D x 4-3/10"H. 6.2 lbs.
Features: • MRI and Air Ambulance Compatible for operation in MRI or on aircraft (tested to U.S. Military Standard 810E for both fixed or rotary winged aircraft environments). • Manual/Auto Selector Switch for automatic ventilation. Override button allows the operator to control the ventilations manually, if required. • Adjustable Peak Airway Pressure allows for differing patient conditions. •, Demand Breathing Capability allows spontaneously breathing patients to breathe on oxygen through the ventilator at their own rate and volume. • Automatic Circuit Shut-Off control shuts off the automatic cycling when the adult patient being ventilated takes a spontaneous breath. Cycling will restart automatically should the patient stop breathing, or if the required volume or respiratory rate drops below a predetermined minimum. • CPAP/PEEP Mode allows for these two functions to be supplied by the ventil-ator without the requirement of an external PEEP value or CPAP device. • Easy to Operate—color-coded, recessed control panel groupings facilitate easy operation and protect knobs. • Audible and Visual Pneumatic Alarms for circuit disconnection, low gas supply pressure, and high airway pressure. The audible high airway pressure alarm alerts the operator to any problems with the patient’s breathing parameters. BSI alarm override control silences the alarm for 15 seconds to allow time for airway management procedures. • Air Mix Mode improves operating time on bottled oxygen for long transports or when 100% O2 is not required. Extremely low drive gas consumption ensures full utilization of the cylinder contents. • Replaceable Cover/Filter is incorporated into the rear of the ventilator to prevent contaminated air from entering into the unit when using the Air Mix Mode. • Pneumatically Powered to eliminate the need for a secondary power source—if you have an approved gas source, you have power to the unit.
Specifications: Minute Volume: 2 to 14 liters • Breaths per minute: 8 to 40 • I:E RATIO: 1:2 • Automatic Flow Rate: 12 to 40 lpm • Manual Flow Rate: As per selected setting • Demand Flow Rate: 0-120 lpm • Demand Triggering Pressure: -5 cm H2O @ 100 lpm • Min. Input Pressure: 45 psi • Max. Input Pressure: 70 psi • Max. Airway Pressure: 60 cm H2O • Oxygen Concentration: 60 or 100% • Adjustable Airway Pressure Range: 20 to 60 cm H2O • Operating Temperature: -18°C to +50°C 0°F to +122°F •, Storage Temperature: -40°C to +60°C, -40°F to + 140°F • Patient Connection: 9/16" DISS • Patient Valve Deadspace: 8 ml • Gas Supply Status Indicator: VISUAL • Circuit Disconnect Alarm: Pulsed Audible, Visual Alarm Silence Control to 15 sec. • Low Input Pressure Alarm: Pulsed Visual and Audible